Meaning
An inline measurement instrument that determines the mass flow rate of a fluid by sensing the inertial forces generated as the fluid moves through vibrating tubes. The coriolis mass meter provides direct mass flow readings without requiring separate temperature or pressure compensation, making it highly accurate for custody transfer. By measuring both density and flow, the device supports industrial processes that require precise ingredient dosing or volumetric conversion.
Phase Measurement
Electromagnetic drive coils vibrate the internal tubes at their natural resonant frequency while sensors at the inlet and outlet detect the movement. As fluid passes through, the resulting coriolis force causes a twist in the tubes, creating a phase difference between the two sensor signals. This phase shift is directly proportional to the mass flow rate of the fluid, allowing the transmitter to compute mass flow dynamically.
High-frequency computation ensures high-precision readings across a wide range of liquid and gas types.
Structural Design
The physical housing contains single or dual measuring tubes constructed from stainless steel or specialized alloys. This assembly must be isolated from external piping vibrations to avoid measurement interference.
Operating Limit
High levels of entrained gas or severe aeration in the liquid stream disrupt the tube vibration and degrade the accuracy of the readings. Under these conditions, the meter may temporarily report errors or fail to measure flow altogether. Thus, the system requires proper air elimination upstream of the sensor to maintain its performance.